Gazelle TECHNO Classic
- Finned heat exchanger made of die-cast aluminium, high efficiency
- Two-channel heat recovery unit made of die-cast aluminium
- Split and extendible air intake and flue gas outlet pipes
- Centrifugal combustion fan
- Two-speed tangential convection fan
- Atmospheric burner and eletronic ignition
- Ionisation flame control
- Microprocessor-controlled electronics
- Instrument panel with lights indicating
- Safety thermostat and safety pressure switch
- Adjustable gas valve
- Automatic HIGH/LOW/OFF settings
- Delayed switch on/off for the convection fan
- Room temperature selector with frost guard setting
- Built-in humidifier
- Day or week timer

TECHNO Classic GAZELLE version combines conventional combustion with an atmospheric burner, advanced design, and electronic control – a feature of the whole range. Optimal design for improved efficiency.
| Model | 3000 |
5000 |
7000 | |
|---|---|---|---|---|
| Height | mm | 550 |
550 |
550 |
| Width | mm | 547 | 667 | 772 |
| Weight | Kg | 22 | 26 | 29 |
| Type |
C13, C53 |
C13, C53 |
C13, C53 |
|
| Category |
II 2H3+ |
II 2H3+ |
II 2H3+ |
|
|
Rated heat input |
W |
3000 |
5000 |
6800 |
|
Reduced heat input |
W |
2100 |
3430 |
5000 |
|
Rated heat output |
W |
2811 |
4610 |
6154 |
|
Reduced heat output |
W |
1940 |
3074 |
4460 |
|
Alimentation |
Nat.gas / LPG |
Nat.gas / LPG |
Nat.gas / LPG |
|
|
Efficiency at rated heat output |
% |
93,7 / 94,2 |
92,2 / 92,8 |
90,5 / 91,4 |
|
Efficiency at reduced heat output |
% |
92,4 / 93,3 |
90,4 / 90,8 |
89,2 / 89,6 |
|
Max NOx value |
mg/kWh |
173,8 / 204 |
79,8 / 111 |
126,3 / 194 |
|
NOx emission class |
3 | 4 | 5 | |
|
Outside diameter of straight outlet pipe |
mm |
55 |
55 |
55 |
|
Outside diameter of split pipes |
mm |
Ø 35 o Ø 60 |
Ø 35 o Ø 60 |
Ø 35 o Ø 60 |
|
Gas coupling diameter |
G 1/2 Maschio |
G 1/2 Maschio |
G 1/2 Maschio |
|
|
Standard natural gas consumption at Pn |
m3/h |
0,317 |
0,529 |
0,719 |
|
Standard LPG consumption at Pn |
Kg/h |
0,237 |
0,395 |
0,537 |
|
Voltage and frequency |
V-Hz |
230-50 |
230-50 |
230-50 |
|
Maximum power consumption |
W | 60 | 82 | 82 |
|
No. of CE certificate |
51BP02706 |
51BP02706 |
51BP02706 |






Fondital