Technical features:
• High-efficiency finned heat exchanger made of die-cast aluminium
• Two-channel heat recovery unit made of die-cast aluminium
• Separate, extendable intake and outlet pipes
• 2-speed centrifugal combustion fan
• 2-speed tangential convection fan
• Pre-mixing gas burner
• Electronic ignition
• Ionization flame control
• Microprocessor-controlled electronics
• Control panel with lights indicating emergency cut-out, minimum power, maximum power, power indicator, overheating and a release button
• Safety air-pressure switch
• Safety thermostat
• Gas valve with constant air-to-gas ratio
• Automatic High-Low-Off settings
• Delayed switch on/off for convection fan
• Ambient temperature selector with frost-guard setting
• Built-in humidifier
• Day or week timer
TECHNICAL DATA
|
| MODEL | | 3000 | 5000 | 7000 |
| Type | | C13, C53 | C13, C53 | C13, C53 |
| Category | | II 2H3+ | II 2H3+ | II 2H3+ |
| Rated heat capacity | W | 3000 | 5000 | 6800 |
| Reduced heat capacity | W | 2100 | 3200 | 5000 |
| Rated thermal power | W | 2760 | 4610 | 6280 |
| Reduced thermal power | W | 1989 | 3030 | 4730 |
| | | | Methan | LPG | | 92 | 93 | | 94,7 | 95,4 | | 31 | 80 | | | Methan | LPG | | 92,2 | 93,6 | | 94,7 | 95,6 | | 29 | 73 | | | Methan | LPG | | 92,3 | 93 | | 94,6 | 95 | | 56 | 127 | |
| | |
| Reduced thermal power | % |
| Efficiency at reduced thermal power | % |
| Max. NOx | mg/kWh |
| NOx emission class | | 5 | 5 | 5 |
| Outside diameter of straight outlet pipes | mm | 55 | 55 | 55 |
| Outside diameter of split pipes | mm | Ø 35 o Ø 60 | Ø 35 o Ø 60 | Ø 35 o Ø 60 |
| Diameter of gas connection | | G 1/2 Male | G 1/2 Male | G 1/2 Male |
| Standard consumption of methane gas at rated power | m3/h | 0,317 | 0,529 | 0,719 |
| Standard consumption of LPG at rated power | Kg/h | 0,237 | 0,395 | 0,537 |
| Power absorbed | W | 50 | 50 | 57 |
| Power voltage and frequency | V-Hz | 230-50 | 230-50 | 230-50 |
| Certificate No | | 51BP02705 |